Open main menu

Biolecture.org β

Detailed explanation of DNA sequencing

Revision as of 13:45, 28 February 2008 by imported>WikiSysop

The term DNA sequencing encompasses biochemical methods for determining the order of the nucleotide bases, adenine, guanine, cytosine, and thymine, in a DNA oligonucleotide. The sequence of DNA constitutes the heritable genetic information in nuclei, plasmids, mitochondria, and chloroplasts that forms the basis for the developmental programs of all living organisms. Determining the DNA sequence is therefore useful in basic research studying fundamental biological processes, as well as in applied fields such as diagnostic or forensic research. The advent of DNA sequencing has significantly accelerated biological research and discovery. The rapid speed of sequencing attainable with modern DNA sequencing technology has been instrumental in the large-scale sequencing of the human genome, in the Human Genome Project. Related projects, often by scientific collaboration across continents, have generated the complete DNA sequences of many animal, plant, and microbial genomes.

DNA Sequence Trace
DNA Sequence Trace

<script type="text/javascript"> //<![CDATA[

if (window.showTocToggle) { var tocShowText = "show"; var tocHideText = "hide"; showTocToggle(); } 

//]]> </script>

 

Contents

Early methods

For thirty years, a large proportion of DNA sequencing has been carried out with the chain-termination method developed by Frederick Sanger and coworkers in 1975[1][2]. Prior to the development of rapid DNA sequencing methods in the early 1970s by Sanger in England and Walter Gilbert and Allan Maxam at Harvard,[3][4] a number of laborious methods were used. For instance, in 1973[5] Gilbert and Maxam reported the sequence of 24 basepairs using a method known as wandering-spot analysis.

RNA sequencing, which for technical reasons is easier to perform than DNA sequencing, was one of the earliest forms of nucleotide sequencing. The major landmark of RNA sequencing, dating from the pre-recombinant DNA era, is the sequence of the first complete gene and then the complete genome of Bacteriophage MS2, identified and published by Walter Fiers and his coworkers at the University of Ghent (Ghent, Belgium).[6][7]

 

Maxam-Gilbert sequencing

In 1976-1977, Allan Maxam and Walter Gilbert developed a DNA sequencing method based on chemical modification of DNA and subsequent cleavage at specific bases [1]. Although Maxam and Gilbert published their chemical sequencing method two years after the ground-breaking paper of Sanger and Coulson on plus-minus sequencing,[8][9] Maxam-Gilbert sequencing rapidly became more popular, since purified DNA could be used directly, while the initial Sanger method required that each read start be cloned for production of single-stranded DNA. However, with the development and improvement of the chain-termination method (see below), Maxam-Gilbert sequencing has fallen out of favour due to its technical complexity, extensive use of hazardous chemicals, and difficulties with scale-up. In addition, unlike the chain-termination method, chemicals used in the Maxam-Gilbert method cannot easily be customized for use in a standard molecular biology kit.

In brief, the method requires radioactive labelling at one end and purification of the DNA fragment to be sequenced. Chemical treatment generates breaks at a small proportion of one or two of the four nucleotide bases in each of four reactions (G, A+G, C, C+T). Thus a series of labelled fragments is generated, from the radiolabelled end to the first 'cut' site in each molecule. The fragments are then size-separated by gel electrophoresis, with the four reactions arranged side by side. To visualize the fragments generated in each reaction, the gel is exposed to X-ray film for autoradiography, yielding an image of a series of dark 'bands' corresponding to the radiolabelled DNA fragments, from which the sequence may be inferred.

Also sometimes known as 'chemical sequencing', this method originated in the study of DNA-protein interactions (footprinting), nucleic acid structure and epigenetic modifications to DNA, and within these it still has important applications.

 

Chain-termination methods

 
 
Part of a radioactively labelled sequencing gel

While the chemical sequencing method of Maxam and Gilbert, and the plus-minus method of Sanger and Coulson were orders of magnitude faster than previous methods, the chain-terminator method developed by Sanger was even more efficient, and rapidly became the method of choice. The Maxam-Gilbert technique requires the use of highly toxic chemicals, and large amounts of radiolabeled DNA, whereas the chain-terminator method uses fewer toxic chemicals and lower amounts of radioactivity. The key principle of the Sanger method was the use of dideoxynucleotides triphosphates (ddNTPs) as DNA chain terminators.

The classical chain-termination or Sanger method requires a single-stranded DNA template, a DNA primer, a DNA polymerase, radioactively or fluorescently labeled nucleotides, and modified nucleotides that terminate DNA strand elongation. The DNA sample is divided into four separate sequencing reactions, containing the four standard deoxynucleotides (dATP, dGTP, dCTP and dTTP) and the DNA polymerase. To each reaction is added only one of the four dideoxynucleotides (ddATP, ddGTP, ddCTP, or ddTTP). These dideoxynucleotides are the chain-terminating nucleotides, lacking a 3'-OH group required for the formation of a phosphodiester bond between two nucleotides during DNA strand elongation. Incorporation of a dideoxynucleotide into the nascent (elongating) DNA strand therefore terminates DNA strand extension, resulting in various DNA fragments of varying length. The dideoxynucleotides are added at lower concentration than the standard deoxynucleotides to allow strand elongation sufficient for sequence analysis.

The newly synthesized and labeled DNA fragments are heat denatured, and separated by size (with a resolution of just one nucleotide) by gel electrophoresis on a denaturing polyacrylamide-urea gel. Each of the four DNA synthesis reactions is run in one of four individual lanes (lanes A, T, G, C); the DNA bands are then visualized by autoradiography or UV light, and the DNA sequence can be directly read off the X-ray film or gel image. In the image on the right, X-ray film was exposed to the gel, and the dark bands correspond to DNA fragments of different lengths. A dark band in a lane indicates a DNA fragment that is the result of chain termination after incorporation of a dideoxynucleotide (ddATP, ddGTP, ddCTP, or ddTTP). The terminal nucleotide base can be identified according to which dideoxynucleotide was added in the reaction giving that band. The relative positions of the different bands among the four lanes are then used to read (from bottom to top) the DNA sequence as indicated.

 
 
DNA fragments can be labeled by using a radioactive or fluorescent tag on the primer (1), in the new DNA strand with a labeled dNTP, or with a labeled ddNTP. (click to expand)

There are some technical variations of chain-termination sequencing. In one method, the DNA fragments are tagged with nucleotides containing radioactive phosphorus for radiolabelling. Alternatively, a primer labeled at the 5’ end with a fluorescent dye is used for the tagging. Four separate reactions are still required, but DNA fragments with dye labels can be read using an optical system, facilitating faster and more economical analysis and automation. This approach is known as 'dye-primer sequencing'. The later development by L Hood and coworkers[10][11] of fluorescently labeled ddNTPs and primers set the stage for automated, high-throughput DNA sequencing.

 
 
Sequence ladder by radioactive sequencing compared to fluorescent peaks (click to expand)

The different chain-termination methods have greatly simplified the amount of work and planning needed for DNA sequencing. For example, the chain-termination-based "Sequenase" kit from USB Biochemicals contains most of the reagents needed for sequencing, prealiquoted and ready to use. Some sequencing problems can occur with the Sanger Method, such as non-specific binding of the primer to the DNA, affecting accurate read out of the DNA sequence. In addition, secondary structures within the DNA template, or contaminating RNA randomly priming at the DNA template can also affect the fidelity of the obtained sequence. Other contaminants affecting the reaction may consist of extraneous DNA or inhibitors of the DNA polymerase.

 

Dye-terminator sequencing

 
 
Capillary electrophoresis (click to expand)

An alternative to primer labelling is labelling of the chain terminators, a method commonly called 'dye-terminator sequencing'. The major advantage of this method is that the sequencing can be performed in a single reaction, rather than four reactions as in the labelled-primer method. In dye-terminator sequencing, each of the four dideoxynucleotide chain terminators is labelled with a different fluorescent dye, each fluorescing at a different wavelength. This method is attractive because of its greater expediency and speed and is now the mainstay in automated sequencing with computer-controlled sequence analyzers (see below). Its potential limitations include dye effects due to differences in the incorporation of the dye-labelled chain terminators into the DNA fragment, resulting in unequal peak heights and shapes in the electronic DNA sequence trace chromatogram after capillary electrophoresis (see figure to the right). This problem has largely been overcome with the introduction of new DNA polymerase enzyme systems and dyes that minimize incorporation variability, as well as methods for eliminating "dye blobs", caused by certain chemical characteristics of the dyes that can result in artifacts in DNA sequence traces. The dye-terminator sequencing method, along with automated high-throughput DNA sequence analyzers, is now being used for the vast majority of sequencing projects, as it is both easier to perform and lower in cost than most previous sequencing methods.

 

Automation and sample preparation

 
 
View of the start of an example dye-terminator read (click to expand)

Modern automated DNA sequencing instruments (DNA sequencers) can sequence up to 384 fluorescently labelled samples in a single batch (run) and perform as many as 24 runs a day. However, automated DNA sequencers carry out only DNA size separation by capillary electrophoresis, detection and recording of dye fluorescence, and data output as fluorescent peak trace chromatograms. Sequencing reactions by thermocycling, cleanup and re-suspension in a buffer solution before loading onto the sequencer are performed separately. In the past, an operator had to trim the low quality ends (see image in the right) of every sequence manually in order to remove the sequencing errors. However, today, software like Fast Chromatogram Viewer can automatically trim the ends at batch.

Large-scale sequencing strategies

Current methods can directly sequence only relatively short (300-1000 nucleotides long) DNA fragments in a single reaction. [2]. The main obstacle to sequencing DNA fragments above this size limit is insufficient power of separation for resolving large DNA fragments that differ in length by only one nucleotide. Limitations on ddNTP incorporation were largely solved by Tabor at Harvard Medical, Carl Fuller at USB biochemicals, and their coworkers[12].

 
 
Genomic DNA is fragmented into random pieces and cloned as a bacterial library. DNA from individual bacterial clones is sequenced and the sequence is assembled by using overlapping regions.(click to expand)

Large-scale sequencing aims at sequencing very long DNA fragments. Even relatively small bacterial genomes contain millions of nucleotides, and the human chromosome 1 alone contains about 246 million bases. Therefore, some approaches consist of cutting (with restriction enzymes) or shearing (with mechanical forces) large DNA fragments into shorter DNA fragments. The fragmented DNA is cloned into a DNA vector, usually a bacterial plasmid, and amplified in Escherichia coli. The amplified DNA can then be purified from the bacterial cells (a disadvantage of bacterial clones for sequencing is that some DNA sequences may be inherently un-clonable in some or all available bacterial strains, due to deleterious effect of the cloned sequence on the host bacterium or other effects). These short DNA fragments purified from individual bacterial colonies are then individually and completely sequenced and assembled electronically into one long, contiguous sequence by identifying 100%-identical overlapping sequences between them (shotgun sequencing). This method does not require any pre-existing information about the sequence of the DNA and is often referred to as de novo sequencing. Gaps in the assembled sequence may be filled by Primer walking, often with sub-cloning steps (or transposon-based sequencing depending on the size of the remaining region to be sequenced). These strategies all involve taking many small reads of the DNA by one of the above methods and subsequently assembling them into a contiguous sequence. The different strategies have different tradeoffs in speed and accuracy; the shotgun method is the most practical for sequencing large genomes, but its assembly process is complex and potentially error-prone - particularly in the presence of sequence repeats. Because of this, the assembly of the human genome is not literally complete — the repetitive sequences of the centromeres, telomeres, and some other parts of chromosomes result in gaps in the genome assembly. Despite having only 93% of the full genome assembled, the Human Genome Project was declared complete because their definition of human genome sequencing was limited to euchromatic sequence (99% complete at the time), excluding these intractable repetitive regions.[13]

 
 
Resequencing steps. Sample prep: Extraction of nucleic acid. Template prep: Amplification and preparation of a small region of the target region. Sequencing steps. (click to expand)

The human genome is about 3 billion (3,000,000,000) bp long;[14] if the average fragment length is 500 bases, it would take a minimum of six million (3 billion/500) to sequence the human genome (not allowing for overlap = 1-fold coverage). Keeping track of such a high number of sequences presents significant challenges, only held down by developing and coordinating several procedural and computational algorithms, such as efficient database development and management.

Resequencing or targeted sequencing is utilized for determining a change in DNA sequence from a "reference" sequence. It is often performed using PCR to amplify the region of interest (pre-existing DNA sequence is required to design the PCR primers). Resequencing uses three steps, extraction of DNA or RNA from biological tissue; amplification of the RNA or DNA (often by PCR); followed by sequencing. The resultant sequence is compared to a reference or a normal sample to detect mutations.

 

New sequencing methods

 

High-throughput sequencing

The high demand for low cost sequencing has given rise to a number of high-throughput sequencing technologies.[15][16] These efforts have been funded by public and private institutions as well as privately researched and commercialized by biotechnology companies. High-throughput sequencing technologies are intended to lower the cost of sequencing DNA libraries beyond what is possible with the current dye-terminator method based on DNA separation by capillary electrophoresis. Many of the new high-throughput methods use methods that parallelize the sequencing process, producing thousands or millions of sequences at once.

In vitro clonal amplification

As molecular detection methods are often not sensitive enough for single molecule sequencing, most approaches use an in vitro cloning step to generate many copies of each individual molecule. Emulsion PCR is one method, isolating individual DNA molecules along with primer-coated beads in aqueous bubbles within an oil phase. A polymerase chain reaction (PCR) then coats each bead with clonal copies of the isolated library molecule and these beads are subsequently immobilized for later sequencing. Emulsion PCR is used in the methods published by Marguilis et al. (commercialized by 454 Life Sciences, acquired by Roche), Shendure and Porreca et al. (also known as "polony sequencing") and SOLiD sequencing, (developed by Agencourt and acquired by Applied Biosystems).[17][18][19] Another method for in vitro clonal amplification is "bridge PCR", where fragments are amplified upon primers attached to a solid surface, developed and used by Solexa (now owned by Illumina). These methods both produce many physically isolated locations which each contain many copies of a single fragment. The single-molecule method developed by Stephen Quake's laboratory (later commercialized by Helicos) skips this amplification step, directly fixing DNA molecules to a surface.[20]

Parallelized sequencing

Once clonal DNA sequences are physically localized to separate positions on a surface, various sequencing approaches may be used to determine the DNA sequences of all locations, in parallel. "Sequencing by synthesis", like the popular dye-termination electrophoretic sequencing, uses the process of DNA synthesis by DNA polymerase to identify the bases present in the complementary DNA molecule. Reversible terminator methods (used by Illumina and Helicos) use reversible versions of dye-terminators, adding one nucleotide at a time, detecting fluorescence corresponding to that position, then removing the blocking group to allow the polymerization of another nucleotide. Pyrosequencing (used by 454) also uses DNA polymerization to add nucleotides, adding one type of nucleotide at a time, then detecting and quantifying the number of nucleotides added to a given location through the light emitted by the release of attached pyrophosphates.[17][21]

"Sequencing by ligation" is another enzymatic method of sequencing, using a DNA ligase enzyme rather than polymerase to identify the target sequence.[22][18][19] Used in the polony method and in the SOLiD technology offered by Applied Biosystems, this method uses a pool of all possible oligonucleotides of a fixed length, labeled according to the sequenced position. Oligonucleotides are annealed and ligated; the preferential ligation by DNA ligase for matching sequences results in a signal corresponding to the complementary sequence at that position.

 

Other sequencing technologies

Other methods of DNA sequencing may have advantages in terms of efficiency or accuracy. Like traditional dye-terminator sequencing, they are limited to sequencing single isolated DNA fragments. "Sequencing by hybridization" is a non-enzymatic method that uses a DNA microarray. In this method, a single pool of unknown DNA is fluorescently labeled and hybridized to an array of known sequences. If the unknown DNA hybridizes strongly to a given spot on the array, causing it to "light up", then that sequence is inferred to exist within the unknown DNA being sequenced.[23] Mass spectrometry can also be used to sequence DNA molecules; conventional chain-termination reactions produce DNA molecules of different lengths and the length of these fragments is then determined by the mass differences between them (rather than using gel separation).[24]

There are new proposals for DNA sequencing, which are in development, but remain to be proven. These include labeling the DNA polymerase,[25] reading the sequence as a DNA strand transits through nanopores,[26] and microscopy-based techniques, such as AFM or electron microscopy that are used to identify the positions of individual nucleotides within long DNA fragments by nucleotide labeling with heavier elements (e.g., halogens) for visual detection and recording.[27] In October 2006 the NIH issued a news release describing novel sequencing techniques and announcing several grant awards.[28]

In October 2006, the X Prize Foundation established the Archon X Prize, intending to award $10 million to "the first Team that can build a device and use it to sequence 100 human genomes within 10 days or less, with an accuracy of no more than one error in every 100,000 bases sequenced, with sequences accurately covering at least 98% of the genome, and at a recurring cost of no more than $10,000 (US) per genome."[29]

 

Major landmarks in DNA sequencing

  • 1953 Discovery of the structure of the DNA double helix.
  • 1972 Development of recombinant DNA technology, which permits isolation of defined fragments of DNA; prior to this, the only accessible samples for sequencing were from bacteriophage or virus DNA.
  • 1975 The first complete DNA genome to be sequenced is that of bacteriophage φX174
  • 1977 Allan Maxam and Walter Gilbert publish "DNA sequencing by chemical degradation" [3]. Fred Sanger, independently, publishes "DNA sequencing by enzymatic synthesis".
  • 1980 Fred Sanger and Wally Gilbert receive the Nobel Prize in Chemistry
  • 1982 Genbank starts as a public repository of DNA sequences.
    • Andre Marion and Sam Eletr from Hewlett Packard start Applied Biosystems in May, which comes to dominate automated sequencing.
    • Akiyoshi Wada proposes automated sequencing and gets support to build robots with help from Hitachi.
  • 1984 Medical Research Council scientists decipher the complete DNA sequence of the Epstein-Barr virus, 170 kb.
  • 1985 Kary Mullis and colleagues develop the polymerase chain reaction, a technique to replicate small fragments of DNA
  • 1986 Leroy E. Hood's laboratory at the California Institute of Technology and Smith announce the first semi-automated DNA sequencing machine.
  • 1987 Applied Biosystems markets first automated sequencing machine, the model ABI 370.
    • Walter Gilbert leaves the U.S. National Research Council genome panel to start Genome Corp., with the goal of sequencing and commercializing the data.
  • 1990 The U.S. National Institutes of Health (NIS) begins large-scale sequencing trials on Mycoplasma capricolum, Escherichia coli, Caenorhabditis elegans, and Saccharomyces cerevisiae (at 75 cents (US)/base).
    • Lipman, Myers publish the BLAST algorithm for aligning sequences.
    • Barry Karger (January[30]), Lloyd Smith (August[31]), and Norman Dovichi (September[32]) publish on capillary electrophoresis.
  • 1991 Craig Venter develops strategy to find expressed genes with ESTs (Expressed Sequence Tags).
    • Uberbacher develops GRAIL, a gene-prediction program.
  • 1992 Craig Venter leaves NIH to set up The Institute for Genomic Research (TIGR).
    • William Haseltine heads Human Genome Sciences, to commercialize TIGR products.
    • Wellcome Trust begins participation in the Human Genome Project.
    • Simon et al. develop BACs (Bacterial Artificial Chromosomes) for cloning.
    • First chromosome physical maps published:
      • Page et al. - Y chromosome[33];
      • Cohen et al. chromosome 21[34].
      • Lander - complete mouse genetic map[35];
      • Weissenbach - complete human genetic map[36].
  • 1993 Wellcome Trust and MRC open Sanger Centre, near Cambridge, UK.
    • The GenBank database migrates from Los Alamos (DOE) to NCBI (NIH).
  • 1995 Venter, Fraser and Smith publish first sequence of free-living organism, Haemophilus influenzae (genome size of 1.8 Mb).
    • Richard Mathies et al. publish on sequencing dyes (PNAS, May)[37].
    • Michael Reeve and Carl Fuller, thermostable polymerase for sequencing[12].
  • 1996 International HGP partners agree to release sequence data into public databases within 24 hours.
    • International consortium releases genome sequence of yeast S. cerevisiae (genome size of 12.1 Mb).
    • Yoshihide Hayashizaki's at RIKEN completes the first set of full-length mouse cDNAs.
    • ABI introduces a capillary electrophoresis system, the ABI310 sequence analyzer.
  • 1997 Blattner, Plunkett et al. publish the sequence of E. coli (genome size of 5 Mb)[38]
  • 1998 Phil Green and Brent Ewing of Washington University publish “phred” for interpreting sequencer data (in use since ‘95)[39].
    • Venter starts new company “Celera”; “will sequence HG in 3 yrs for $300m.”
    • Applied Biosystems introduces the 3700 capillary sequencing machine.
    • Wellcome Trust doubles support for the HGP to $330 million for 1/3 of the sequencing.
    • NIH & DOE goal: "working draft" of the human genome by 2001.
    • Sulston, Waterston et al finish sequence of C. elegans (genome size of 97Mb)[40].
  • 1999 NIH moves up completion date for rough draft, to spring 2000.
    • NIH launches the mouse genome sequencing project.
    • First sequence of human chromosome 22 published[41].
  • 2000 Celera and collaborators sequence fruit fly Drosophila melanogaster (genome size of 180Mb) - validation of Venter's shotgun method. HGP and Celera debate issues related to data release.
    • HGP consortium publishes sequence of chromosome 21.[42]
    • HGP & Celera jointly announce working drafts of HG sequence, promise joint publication.
    • Estimates for the number of genes in the human genome range from 35,000 to 120,000. International consortium completes first plant sequence, Arabidopsis thaliana (genome size of 125 Mb).
  • 2001 HGP consortium publishes Human Genome Sequence draft in Nature (15 Feb)[43].
    • Celera publishes the Human Genome sequence[44].
  • 2005 420,000 VariantSEQr human resequencing primer sequences published on new NCBI Probe database.
  • 2007 For the first time, a set of closely related species (12 Drosophilidae) are sequenced, launching the era of phylogenomics.
    • Craig Venter publishes his full diploid genome: the first human genome to be sequenced completely.

 

See also

  • Sequencing
  • Genome project - how entire genomes are assembled from these short sequences.
  • Applied Biosystems - provided most of the chemistry and equipment for the genome projects. Next-generation technology for very high data generation rates.
  • 454 Life Sciences - company specializing in high-throughput DNA sequencing using a sequencing-by-synthesis approach.
  • Illumina (company) - Advancing genetic analysis one billion bases at a time; whole genome sequencing.
  • Joint Genome Institute - sequencing center from the US Department of Energy whose mission is to provide integrated high-throughput sequencing and computational analysis to enable genomic-scale/systems-based scientific approaches to DOE-relevant challenges in energy and the environment.
  • DNA field-effect transistor
  • For a description of the basic technology for tagging DNA with high Z atoms for direct imaging using transmission electron microsopy [TEM] and sequencing strands of >10,000 bp per image captured, see High Z tagging technology.

 

Citations

  1. ^ Sanger F, Coulson AR. A rapid method for determining sequences in DNA by primed synthesis with DNA polymerase. J Mol Biol. 1975 May 25;94(3):441–448
  2. ^ F. Sanger, S. Nicklen, and A. R. Coulson, DNA sequencing with chain-terminating inhibitors, Proc Natl Acad Sci U S A. 1977 December; 74(12): 5463–5467
  3. ^ Maxam AM, Gilbert W., A new method for sequencing DNA, Proc Natl Acad Sci U S A. 1977 Feb;74(2):560-4
  4. ^ http://nobelprize.org/nobel_prizes/chemistry/laureates/1980/gilbert-lecture.pdf
  5. ^ Proc Natl Acad Sci U S A. 1973 December; 70(12 Pt 1-2): 3581–3584. The Nucleotide Sequence of the lac Operator, Walter Gilbert and Allan Maxam
  6. ^ Min Jou W, Haegeman G, Ysebaert M, Fiers W., Nucleotide sequence of the gene coding for the bacteriophage MS2 coat protein, Nature. 1972 May 12;237(5350):82-8
  7. ^ Complete nucleotide sequence of bacteriophage MS2 RNA: primary and secondary structure of the replicase gene. Nature. 1976 Apr 8;260(5551):500-7.
  8. ^ Sanger, F. & Coulson, A. R. (1975) J. Mol. Biol. 94, 441-448
  9. ^ http://nobelprize.org/nobel_prizes/chemistry/laureates/1980/sanger-lecture.pdf
  10. ^ Nature. 1986 Jun 12-18;321(6071):674-9. Fluorescence detection in automated DNA sequence analysis. We have developed a method for the partial automation of DNA sequence analysis. Fluorescence detection of the DNA fragments is accomplished by means of a fluorophore covalently attached to the oligonucleotide primer used in enzymatic DNA sequence analysis. A different coloured fluorophore is used for each of the reactions specific for the bases A, C, G and T. The reaction mixtures are combined and co-electrophoresed down a single polyacrylamide gel tube, the separated fluorescent bands of DNA are detected near the bottom of the tube, and the sequence information is acquired directly by computer.
  11. ^ Nucleic Acids Res. 1985 Apr 11;13(7):2399-412. The synthesis of oligonucleotides containing an aliphatic amino group at the 5' terminus: synthesis of fluorescent DNA primers for use in DNA sequence analysis. Note that Oxford University Press, the publishers of the journal Nucleic Acids Research, make the full contents of this journal available online for free - you can download a copy of this paper for yourself !!
  12. ^ a b (1995-08-31) "A novel thermostable polymerase for DNA sequencing.". Nature 376 (6543): 796-797. PMID 7651542. Retrieved on 2007-10-08.
  13. ^ International Human Genome Sequencing Consortium (2004). "Finishing the euchromatic sequence of the human genome.". Nature 431 (7011): 931-45. PMID 15496913. paper available online
  14. ^ Human Genome Project Information
  15. ^ Neil Hall (2007). "Advanced sequencing technologies and their wider impact in microbiology". The Journal of Experimental Biology 209: 1518-1525.
  16. ^ G.M. Church (2006). "Genomes for ALL". Scientific American 294 (1): 47-54. PMID 16468433.
  17. ^ a b M. Margulies, et al. (2005). "Genome sequencing in microfabricated high-density picolitre reactors". Nature 437: 376-380.
  18. ^ a b J. Shendure, G.J. Porreca, N.B. Reppas, X. Lin, J.Pe McCutcheon, A.M. Rosenbaum, M.D. Wang, K. Zhang, R.D. Mitra and G.M. Church. "Accurate Multiplex Polony Sequencing of an Evolved Bacterial Genome". Science 309 (5741): 1728-1732.
  19. ^ a b http://solid.appliedbiosystems.com/ - Applied Biosystems' SOLiD technology
  20. ^ Braslavsky, I., Hebert, H., Kartalov, E. and Quake, S.R. (2003). "Sequence information can be obtained from single DNA molecules". Proceedings of the National Academy of Sciences of the United States of America 100: 3960–3964.full text available online
  21. ^ M. Ronaghi, S. Karamohamed, B. Pettersson, M. Uhlen, and P. Nyren (1996). "Real-time DNA sequencing using detection of pyrophosphate release". Analytical Biochemistry 242: 84=89.
  22. ^ S. C. Macevicz, US Patent 5750341, filed 1995
  23. ^ G.J. Hanna, V.A. Johnson, D.R. Kuritzkes, D.D. Richman, J. Martinez-Picado, L. Sutton, J.D. Hazelwood, R.T. D'Aquila (2000). "Comparison of sequencing by hybridization and cycle sequencing for genotyping of human immunodeficiency virus type 1 reverse transcriptase". Journal of Clinical Microbiology 38 (7): 2715. PMID 10878069.
  24. ^ J.R. Edwards, H.Ruparel, and J. Ju. "Mass-spectrometry DNA sequencing". Mutation Research 573 (1-2): 3-12.
  25. ^ VisiGen Biotechnologies Inc. - Technology Overview
  26. ^ The Harvard Nanopore Group
  27. ^ USPTO application # 20060029957 assigned to ZS genetics http://www.freepatentsonline.com/20060029957.html
  28. ^ NHGRI Aims to Make DNA Sequencing Faster, More Cost Effective, NIH News Release, 4 October 2006
  29. ^ "PRIZE Overview: Archon X PRIZE for Genomics"
  30. ^ Karger, Barry L.; A. Guttman, A. S. Cohen, D. N. Heiger (1990-01-15). "Analytical and micropreparative ultrahigh resolution of oligonucleotides by polyacrylamide gel high-performance capillary electrophoresis". Analytical Chemistry 62 (2): 137 - 141. doi:10.1021/ac00201a010. Retrieved on 2007-10-08.
  31. ^ Smith, Lloyd M.; Luckey JA, Drossman H, Kostichka AJ, Mead DA, D'Cunha J, Norris TB (1990-08-11). "High speed DNA sequencing by capillary electrophoresis.". Nucleic Acids Research 18: 4417-4421. PMID 2388826 doi:10.1093/nar/18.15.4417. Retrieved on 2007-10-08.
  32. ^ Dovichi, Norman J.; H.P. Swerdlow, S. Wu , H.R. Harke (1990-09-07). "Capillary gel electrophoresis for DNA sequencing: laser-induced fluorescence detection with the sheath flow cuvette". Journal of Chromatography 516: 61-67. PMID 2286629. Retrieved on 2007-10-08.
  33. ^ Page, DC; Foote S, Vollrath D, Hilton A (1992-10-02). "The human Y chromosome: overlapping DNA clones spanning the euchromatic region.". Science 258 (5079): 60-66. PMID 1359640. Retrieved on 2007-10-08.
  34. ^ Cohen, Daniel; Ilya Chumakov, Philippe Rigault, Sophie Guillou, Pierre Ougen, Alain Billaut, Ghislaine Guasconi, Patricia Gervy, Isabelle LeGall, Pascal Soularue, Laurent Grinas, Lydie Bougueleret, Christine Bellanné-Chantelot, Bruno Lacroix, Emmanuel Barillot, Philippe Gesnouin, Stuart Pook, Guy Vaysseix, Gerard Frelat, Annette Schmitz, Jean-Luc Sambucy, Assumpcio Bosch, Xavier Estivill, Jean Weissenbachparallel, Alain Vignal, Harold Riethman, David Cox, David Patterson, Kathleen Gardiner, Masahira Hattori, Yoshiyuki Sakaki, Hitoshi Ichikawa, Misao Ohki, Denis Le Paslier, Roland Heilig, Stylianos Antonarakis (1992-10-01). "Continuum of overlapping clones spanning the entire human chromosome 21q". Nature 359 (6394): 380-387. PMID 1406950 doi:10.1038/359380a0. Retrieved on 2007-10-08.
  35. ^ Lander, E. S.; Dietrich W, Katz H, Lincoln SE, Shin HS, Friedman J, Dracopoli NC (1992-06). "A Genetic Map of the Mouse Suitable for Typing Intraspecific Crosses". Genetics 131: 423-447. PMID 1353738. Retrieved on 2007-10-08.
  36. ^ Weissenbach, Jean; Gyapay G, Dib C, Vignal A, Morissette J, Millasseau P, Vaysseix G, Lathrop M. (1992-10-29). "A second-generation linkage map of the human genome". Nature 359: 794 - 801. PMID 1436057 doi:10.1038/359794a0. Retrieved on 2007-10-08.
  37. ^ Mathies, R. A.; Ju J, Ruan C, Fuller CW, Glazer AN (1995-05-09). "Fluorescence Energy Transfer Dye-Labeled Primers for DNA Sequencing and Analysis". PNAS 92: 4347-4351. PMID 7753809. Retrieved on 2007-10-08.
  38. ^ (1997-09-05) "The Complete Genome Sequence of Escherichia coli K-12". Science 277 (5331): 1453-1462. PMID 9278503 doi:10.1126/science.277.5331.1453. Retrieved on 2007-10-08.
  39. ^ (1998-03) "Base-calling of automated sequencer traces using phred. II. Error probabilities.". Genome Reserarch 8 (3): 186-94. PMID 9521922. Retrieved on 2007-10-08.
  40. ^ (1998-12-11) "Genome Sequence of the Nematode C. elegans: A Platform for Investigating Biology". Science 282 (5396): 2012-2018. PMID 9851916 doi:10.1126/science.282.5396.2012. Retrieved on 2007-10-08.
  41. ^ (1999-12-02) "The DNA sequence of human chromosome 22". Nature 402 (6761): 489-495. PMID 10591208. Retrieved on 2007-10-08.
  42. ^ Hattori, M., A. Fujiyama, T. D. Taylor, H. Watanabe, T. Yada, H.-S. Park, A. Toyoda, K. Ishii, Y. Totoki, D.-K. Choi, E. Soeda, M. Ohki, T. Takagi, Y. Sakaki; S. Taudienk, K. Blechschmidtk, A. Polleyk, U. Menzelk, J. Delabar, K. Kumpfk, R. Lehmannk, D. Patterson, K. Reichwaldk, A. Rumpk, M. Schillhabelk, A. Schudyk, W. Zimmermannk, A. Rosenthalk; J. KudohI, K. ShibuyaI, K. KawasakiI, S. AsakawaI, A. ShintaniI, T. SasakiI, K. NagamineI, S. MitsuyamaI, S. E. Antonarakis, S. MinoshimaI, N. ShimizuI, G. Nordsiek, K. Hornischer, P. Brandt, M. Scharfe, O. SchoÈn, A. Desario, J. Reichelt, G. Kauer, H. Bloecker; J. Ramser, A. Beck, S. Klages, S. Hennig, L. Riesselmann, E. Dagand, T. Haaf, S. Wehrmeyer, K. Borzym, K. Gardiner, D. Nizetickk, F. Francis, H. Lehrach, R. Reinhardt, and M.-L. Yaspo, (2000). The DNA sequence of human chromosome 21. Nature 405: 311-319.
  43. ^ (2001-02-15) "Initial sequencing and analysis of the human genome". Nature 409 (6822): 860-921. PMID 11237011. Retrieved on 2007-10-08.
  44. ^ Venter, J. C.; et al (2001-02-16). "The sequence of the human genome.". Science 291 (5507): 1304-51. PMID 11181995 doi:10.1126/science.1058040. Retrieved on 2007-10-08.

External links